joyce@huhanggroup.net
+86 18050866257
Home > Products > Drain Valve > Pressure Differential Principle Backflow Preventer Check Valve

Pressure Differential Principle Backflow Preventer Check Valve

Detail

Basic Info.

Model NO.
HA005
Sealing Form
Gland Packings Globe Valve
Flow Direction
Unidirection
Standard
BS, ANSI,En, ISO, GB
Application
Industrial Usage, Water Industrial Usage, Household Usage
Transport Package
Export Standard Packagea
Specification
DN40-DN600
Trademark
huhang
Origin
China
Production Capacity
50000PCS/Month

Product Description

1. Product Overview
        The HA005-4X-10/16Q Pressure Differential Principle Check Valve is a patented product independently developed by our company.
        The product is used at the cross-connection point between domestic drinking water and non-drinking water pipelines to prevent the backflow contamination of the medium.
        1)Pressure differential principle, zero backflow;
        2)No pressure reduction at the inlet, saving 25% energy;
        3)Innovative invention, dual-chamber control;
        4)All internal components made of stainless steel or copper alloy, pollution-free;
        5)Compact straight-through structure;
        6)Invention patent number: ZL 2013 1 0718280.5
           Utility model patent: ZL 2013 2 0855732.X
2. Technical Parameters
Pressure Differential Principle Backflow Preventer Check Valve3. Operating Principle
        1)The opening and closing of the main valve in the pressure differential principle check valve.
        When the pressure differential principle check valve supplies water downstream, the gate valve at the outlet opens, and the water in the middle chamber flows downstream through the outlet. The pressure P2 also decreases. At this point, the left side pressure P1 of the elbow piston overcomes the pressure of the spring on the right side (PZh), pushing the piston to move to the right side as shown in the diagram, and simultaneously opening the main valve with the quick-opening valve disc. At this moment, the inlet valve has to overcome the additional loss of the spring. The medium flows from the outer sides of the valve disc to the middle chamber and supplies water downstream. As the flow rate increases, P2 continues to decrease, and the piston continues to move to the right until the main valve is fully open.
        When water supply downstream is not required, the water supply valve at the outlet will be closed. During this process, the pressure in the middle chamber will rise, pushing the piston to move to the left side as shown in circle 3 until fully closed.
        2)The opening and closing of the pressure differential principle check valve's drain valve.
        According to the national standard: "When P1-P2 is 14 KPa, the drain valve should automatically open for drainage. When the pressure difference P1-P2 continuously decreases, the drain valve should continue draining until the drain valve is fully open, making the middle chamber empty, and forming an air gap between the inlet chamber and the middle chamber.
Due to the drainage from the drain valve, P2 decreases. When P1-P2 is less than 14 KPa, the drain valve automatically closes, effectively preventing the backflow of the medium.
        If, under the mentioned conditions, P1 continues to decrease, the drain valve will continuously open until it is fully open, emptying the water from the middle chamber, turning it into an empty space. This achieves an air gap between the inlet chamber and the middle chamber, preventing any backflow from the middle chamber to the inlet chamber under any operating conditions.
Pressure Differential Principle Backflow Preventer Check Valve 4.Typical Installation Schematic
Pressure Differential Principle Backflow Preventer Check Valve


Pressure Differential Principle Backflow Preventer Check ValveQuality and inspection:
       Regular check on production line at each working procedure, and one special inspector inspecting the goods in random during the period time of production.regular performance check on finished goods.        
Production step:

       1.The raw materials are cast or forged and processed into semi-finished products.
       2.Processing the semi-products in works shop
       3.Assembling the goods
       4.Testing the sealing in pressure and checking quality of the goods
       5.Package
       6.Delivery the goods on time
Package:
        1.The pakage standard:inside PVC bag and small box and standard export carton
        2.If you have any special requirements pakage,we can pakage as per your artworks.
Primary Competitive Advantages:
       1) We have several years of experience in manufacturing various types of valves professionally.
       2) Products are of good quality, with reasonable prices.
       3) Our style:Promise must be kept and action must be prompt and fruitful.
Certifications

 

Pressure Differential Principle Backflow Preventer Check ValvePressure Differential Principle Backflow Preventer Check Valve
       Our business idea:All for customers and everything from innovation.
The size standards can be customized according to your specific requirements. Please feel free to contact us for more details.

Looking forward to your inquiry for this MDF Raw Milled ————

Related Tags:

Related Products

Share

Related Searches

Contact Us

Email:joyce@huhanggroup.net
Phone:+86 18050866257